This one went deep. New foundations and steelwork to open up the kitchen and dining space, drainage rebuilt and a manhole moved, then a timber frame extension built off Marmox Thermoblock to keep the cold out of the base.
The frame was wrapped externally in Steico wood fibre board and Pro Clima Solitex Plus, made airtight with Finsa SuperPan VapourStop board and Tescon Vana tape, then blown full of Warmcel cellulose through the walls, roof and floor. The existing house was not left out: its suspended floors were lifted and insulated with Steico Flex over a breathable membrane. Underfloor heating runs off a heat pump, and the whole thing finishes in silicone render with a mosaic plinth.
Adam & his wonderful team have transformed our house and been brilliant, professional and friendly throughout. Everyone has been so respectful of our home and the work has been done to the highest standards. Great communication every step of the way too - we always knew how it was going and how long things would take. There was never a danger of the project running over or going over budget - we were kept in the loop and involved in all decision making every step of the way. Can't recommend them highly enough.

Excavation for foundations and for terrace with underfloor storage

Foundation

Temporary supports for installing new structural steel in Finchley

Steel picture frame installed for extension in Finchley

Steelwork installation in Finchley

Steelwork is in place for extending the kitchen and dining

New manhole, connecting sewer pipes

Blockwork below DPC and moving the manhole, rebuilding drainage for extension

Marmox Thermoblock and new sewer connection

Marmox Thermoblock base for Timber frame extension in Finchley, London

Building floor structure with I-joists for extension in Finchley

Building timber frame walls with external wood fibre insulation board

Walls and roof are built with timber frame for extension

I-joists used for roof structure in extension

Installation of wall structure with I-joists

New I-joist roof for extension

Rear elevation for extension - timber frame with wood fibre external wall insulation

Installation of Steico wood fibre external wall insulation boards

Installation of Steico wood fibre external insulation boards for timber frame extension

Installation of Pro Clima Solitex Plus Reinforced windtight breathable roofing membrane

Installation of Pro Clima Solitex Plus Reinforced windtight breathable roofing membrane

Airtightness work as the extension roof joins the existing building

Installing Finsa SuperPan VapourStop Airtightness board to extension roof and walls

Preparation for blowing cellulose Warmcel insulation to timber frame

Preparation for blowing cellulose insulation to roof floor and walls

Preparation works for blowing Warmcel cellulose insulation into new extension floor structure

Warmcel cellulose blown into ceiling

Blowing Warmcel cellulose insulation into walls and ceilings with XFloc machine

Warmcel cellulose insulation to floor

Warmcel cellulose insulation blown-in, Finsa airtight vapour barrier racking board taped

Existing floor is insulated with Steico flexible wood fibre batts

Installation of ProClima Solitex Plus breathable membrane before existing floor insulation

Installation of ProClima Solitex Plus breathable membrane before floor insulation

Installation of Steico Flex wood fibre batts to existing floor in Finchley

Floor insulation completed: new extension floor with blown-in cellulose and existing floor with wood fibre

Installation of wet underfloor heating system

Underfloor heating installed with aluminium spreader plates

Underfloor heating runs from manifold to rooms

Underfloor heating pipe and manifold for heat pump

Tescon Vana airtightness tapes used on floor insulation

Suspended floor insulation completed

Decoration and bamboo flooring completed

Bathroom decorated

Bathroom refurbished

Hallway decorated bamboo floor installed over underfloor heating

Kitchen wallpaper and paint

Toilet wallpaper decoration and lighting

Wallpaper to kitchen

Flat roof completed with Aluminium Parapet Coping

Plinth insulation with grey mosaic render
Breathable silicone render finish and mosaic render on plinth insulation

External wall insulation with UPVC window sills

External wall insulation with UPVC window sill

Plinth insulation render being applied

Banister installed

External patio stairs and paving installed

External patio, paving and banister installed

Paving and heat pump in rear garden

Rear extension completed with heat pump and patio in Finchley
If you are extending and the rest of the house is cold, it is usually cheaper to do both at once than to come back for the second half later.